ETCR ETCR6200 AC/DC Clamp Meter Current Tester



[주요 사항]

. Introduction
ETCR6200 AC/DC Leakage Current Clamp Meter also named: Car Leakage Current Clamp Meter, Car Standby Current Clamp Meter, Car Inrush current Tester, Car Charge Current Tester. It is specially designed for online measurement of AC/DC leakage current, current below 600V by adopting up-to-date CT technology and digital integration technology. It is especially suitable for measure car standby current, leakage current, inrush current. It is a product with the characteristic of relatively small size, high accuracy, strong anti-interference capability and automatic shifting. It is apply to car leakage rapid detection, consumed current detection, quickly find the fault of the wire broke leakage, equipment fled electric, line contact with iron, measuring the motor inrush current and alternator charge current etc. It could be widely use in those fields as car repair, car leave factory test, car parts test, the current detection in telecommunication room, electric power overhauling, meteorology, oil detection, etc.
It has those functions as peak holding, data holding and data storage. It obtains one RS232 interface, communication cable and software, through the computer, it can online real-time monitoring, historical query, dynamic display, MIN-AVG-MAX indication, alarm setting and indicating, data reading, saving and printing.



. Technical Specification
Model
ETCR6200
Function
Measurement of AC/DC current, leakage current, repairing the car circuit.
Power Supply
Zn-Mn dry battery,6F22,9V, continuous use for 30h
Test Mode
Clip-on CT, noncontact measurement
Clamp Size
25mmX35mm
Measurement Range
0mA~60.0A AC/DC
Resolution
1mA AC/DC
Accuracy
±2%rdg±5dgt (23℃±5℃, below 75%rh)
Display Mode
Four digits LCD display
Dimension
LWH: 168mm×65mm×34mm
LCD Dimension
35mm×21.5mm; display domain: 32mm×15mm
Sampling Rate
2 times/s
Frequency
AC: 45Hz-400Hz
Polarity Indication
DC current auto identified and display“—”
Test Position
Tested wire in the jaw center
Range Shift
Automatically
Line Voltage
Do not exceed AC 600V
RS232 Interface
Data stored in the memory of the meter via RS232 upload to PC
Com-Configure
Baud rate:9600, data bit:8, stop bit:1, check bit: NONE
Data Memory
99 units, FULL blinks when the memory is full
Reading Hold
DH indicating the reading is hold
Out of Range
OL indicating the current is out of range
Auto Power-off
5 Minutes after power on, it will power off automatically to lower the power consumption
Battery Voltage
    Indicating the battery voltage is lower than 7.2V.Then the battery have to be changed.
Weight
180g (including the battery)
Working Current
10mA
Humiture
-10℃-50℃,below 80%rh
Limit Temperature Error
-10℃-0℃ and 40℃-50℃, within 2%rdg
Humiture Storage
-10℃-60℃,below 70%rh
Insulating Strength
AC 3700V/rms. (between the alloy of the clamp and the housing)
Applicable safety rules
IEC1010-1, IEC1010-2-032, pollution:2, CAT Ⅲ(600V)
Accessories
Meter: 1pc; toolkit: 1pc; RS232 communication line: 1pc; disk: 1pc; case: 1pc.